DKK-TOA

  • Filter

Enables measurement of CO2 in both liquid phase and gas phase Wide measurement range(0.1 - 100%) Membrane electrode allows for reliable measurement Power-saving design; rechargeable battery adaptable Waterproof design(IP67: 1m depth, up to 30mins) Meas. range Liquid phase: 1.49 - 1490 mg/L Gas phase: 0.1 - 100%

Concentration of acid and alkali measurable High concentration range measurable by electromagnetic method Analog output enables easy continuous measurement Switchable concentration and conductivity rate Easy maintenance requires no daily calibration Meas. range (conductivity rate) 0 - 200 S/m

Handheld Surface Salinity Meter SSM-21P Compliant with PSPC  Ideal for surface salinity measurements of paints used in ship coatings  Simple operation (just attach the cell to the meter and inject pure water into the cell)   Measurement range 0 - 199.9mg/m2, 0 - 1999mg/m2 0 - 199.9μS/cm, 0 - 1.999mS/cm 0 - 50℃

Category: pH meters

Cost-effective basic model Easy-to-read large customized LCD display High-performance with the Strong&Float (internal solution concentration checker) pH electrode External printer connectable Data storage up to 300 points  Meas. range pH 0.00 - 14.00 ORP 0 - ±2000.0 mV (ORP electrodes sold separately) 0 - 100.0 degrees C

Industrial ORP Transmitter HDM-137A(2-wire)/HDM-138A(4-wire) Easy-to-use ORP analyzer for field installation in a compact and rigid aluminum enclosure Automatic check done with standard solution Auto-detection of electrode deterioration Alterable output range Automated self-diagnosis of fault (burn-out output) Meas. range -2000 - +2000mV

Handheld ORP Meter RM-30P Dedicated model for ORP measurement Power-saving design; rechargeable battery adaptable Waterproof design (IP67: 1m depth, up to 30mins) Data storage up to 1000 points  Meas. range 0 - ±2000 mV 0 - 100.0 degrees C

Industrial Conductivity Transmitter WBM-160 (4-wire) Multi-function conductivity analyzer for field installation in a compact aluminum diecast enclosure Wide application range from ultrapure water to wastewater 2-point contact signal, 2-channel output including temperature (RS-232 optional) Power supply: AC90 - 264V, 50/60Hz   Meas. range Minimum : 0 - 0.2 μS/cm Maximum : 0 - 20 mS/cm

Panel Type Resistivity Analyzer AQM-210A Compact DIN 96 size Best suited for water quality control in ultra-pure water production lines  Two detectors connectable RS-232 equipped as standard specification Output: 2-channel, insulated, 4 - 20mA Meas. range 0.00 - 20.00 MΩ・cm