Industrial Conductivity Transmitter WBM-160 (4-wire) Multi-function conductivity analyzer for field installation in a compact aluminum diecast enclosure Wide application range from ultrapure water to wastewater 2-point contact signal, 2-channel output including temperature (RS-232 optional) Power supply: AC90 - 264V, 50/60Hz   Meas. range Minimum : 0 - 0.2 μS/cm Maximum : 0 - 20 mS/cm

Conductivity Transmitter with HART Interface WBM-165H (2-wire) HART communication protocol interface with a 2-wire, 24 VDC circuit Aluminum diecast enclosure, digital display and a wide range of other useful features One-touch auto calibration Self-diagnostic function Meas. range Minimum : 0 - 0.2 μS/cm Maximum : 0 - 20 mS/cm

Compact DIN 96 size Temperature compensation computed by a microcomputer  Cell constant value adjustable depends on customers' need Water temperature displayable Power supply: AC90 - 264V, 50/60Hz Meas. range Minimum : 0 - 0.2 μS/cm Maximum : 0 - 20 mS/cm

Compact DIN 96 size Conductivity meter with built-in microcomputer for various applications such as ultra-pure water production, boiler plants, foodstuff plants, etc. Two detectors connectable  RS-232 equipped as standard specification Output: 2-channel, insulated, 4 - 20mA Meas. range Minimum : 0 - 0.2 μS/cm Maximum: 0 - 20 mS/cm

Sanitary Type Conductivity Analyzer/Detector WBM-121A / AK Cell Compact DIN 96 size Designed for sanitary conductivity analyzer for the food industry Applied in foodstuff plants and installed in pipes and tanks. Best suited for CIP (stationary cleaning) management, debubbling agent control and liquid level management Meas. range 0 - 300/3000 μS/cm (at 25 degrees C) 0 - 20/200 mS/cm (at 25 degrees C)

Single-function (no indication) conductivity analyzer for field installation Easy installation for the one-unit amplifier and detector Output: 4 - 20mADC Power supply: 100VAC  Meas. range AA-1: 0 - 2 μS/cm to 0 - 10000 μS/cm AA-2: 0 - 0.2/0.5/1.0 μS/cm

Hermetically sealed 2-electrode type detector featured with excellent heat-proofing and pressure tightness Pipeline-insertion/immersion/flow-through/throw-in/leadless, etc. type available Four types of cell constants available: 0.01, 0.1, 1.0, 10 cm-1 Meas. range Minimum : 0 - 0.2 μS/cm Maximum : 0 - 20 mS/cm