The Fluke 572-2 High Temperature Infrared Thermometer is the one product your customers need for high-temperature industrial environments. With a straight-forward user interface, the Fluke 572-2 makes even complex measurements easy. With a rugged, easy-to-use, ergonomic design, the Fluke 575-2 can stand up to tough industrial, electrical, and mechanical environments.

Specification
IR Temperature Range -30 °C to 900 °C (-22 °F to 1652 °F)
IR Accuracy
Calibration geometry with ambient temperature 23 °C±2 °C)
<0 °C: ±(1.0 °C + 0.1 °/1 °C)
≥0 °C: ±1 % of reading or ± 1.0 °C, whichever is greater
<32 °F: ±(2 °F ±0.1 °/1 °F)
≥32 °F: ±1 % or ±2 °F, whichever is greater
IR Repeatability ±0.5 % of reading or ±0.5 °C (±1 °F), whichever is greater.
Display Resolution 0.1 °C / 0.1 °F
Spectral Response 8 μm to 14 μm
Response Time (95 %) <500 ms
K-Type Thermocouple Input Temperature Range -270 °C to 1372 °C (-454 °F to 2501 °F)
K-Type Thermocouple Input Accuracy
(with ambient temperature 23 °C±2 °C)
<-40 °C: ±(1 °C + 0.2 °/1 °C)
≥-40 °C: ±1 % or 1 °C, whichever is
<-40 °C: ±(1 °C + 0.2 °/1 °C)
≥-40 °C: ±1 % or 1 °C, whichever is
K-Type Thermocouple Repeatability ±0.5 % of reading or ±0.5 °C (±1 °F), whichever is greater
K-Type Thermocouple Input Accuracy (with ambient temperature 23 °C±2 °C) <-40 °C: ±(1 °C + 0.2 °/1 °C)
≥-40 °C: ±1 % or 1 °C, whichever is greater
<-40 °C: ±(1 °C + 0.2 °/1 °C)
≥-40 °C: ±1 % or 1 °C, whichever is
K-Type Thermocouple Repeatability ±0.5 % of reading or ±0.5 °C (±1 °F), whichever is greater
K-Type Thermocouple Resolution 0.1 °C/0.1 °F
Distance:Spot 0:1(calculated at 90 % energy)
Laser sighting Offset dual laser, output <1 mW
Data storage 99 points
Power 2 AA Batteries

Location