Fluke
Sub Categories
Rugged fabric holster includes flap for lead storage and built-in belt loop Fits Fluke T3 and T5 testers One year warranty
Measuring Range selectable per software:0.01A to 1A0.1A to 10A Peak current for sinusoidal currents:3.7A to 37A Intrinsic error: 0.5% Frequency Range: 40Hz to 10kHz Operating Voltage: 300V CAT IV Phase Error: 0.5° Jaw Opening: <15mm diameter or 15x17mm bus bars Errors in % of measuring range at 23°C ± 2K; 74°F±2K, for 48 to 65Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts)
Measuring Range selectable per software:0.2 A to 20 A 2 A to 200 A Peak current for sinusoidal currents74 A 300 A Intrinsic error 0.5% Frequency Range 40 Hz to 10 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening < 15 mm diameter or 15 x 17 mm bus bars Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts)
Hose and fittings to connect directly to the Fluke 700HTP-1 test pressure port Includes plugs and caps to eliminate fluid loss in hose, eliminates the need to re-prime the hose. Self-sealing fittings with easy finger tight connections. Low volumetric expansion and a negligible pressure drop at rated pressures One year warranty Includes: Hose with (2) 1/4" NPT female output connections (2) adapters that to convert ¼: NPT female to 1/4" NPT male (include sealing caps) 1/4 in NPT female to 1/4 in BSP male adapter Instruction sheet
One pair (red, black) of nickel plated clips Profile narrows to 5.6 mm at tip, hook opening 6.4mm at front, 2 mm at base Recommended for use with TL222 and TL224 test leads CAT IV 600 V, CAT III 1000 V, 3 A rating. UL listed
Durable nylon construction protects your thermometer while keeping it within reach Velcro closures provide quick access and a secure closure Extra accessory pocket for storing temperature probe Snap-open loop attaches easily to your belt
Measuring Range selectable per software:0.2 A to 20 A 2 A to 200 A Peak current for sinusoidal currents74 A 300 A Intrinsic error 0.5% Frequency Range 40 Hz to 10 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening < 15 mm diameter or 15 x 17 mm bus bars Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts)
Measuring Range selectable per software 1 A to 100 A 5 A to 500 A Peak current for sinusoidal currents 240 A 1350 A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening 45 cm length 2 m cable Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts)