Fluke

  • Filter

Rugged fabric holster includes flap for lead storage and built-in belt loop Fits Fluke T3 and T5 testers One year warranty

Measuring Range selectable per software:0.01A to 1A0.1A to 10A Peak current for sinusoidal currents:3.7A to 37A Intrinsic error: 0.5% Frequency Range: 40Hz to 10kHz Operating Voltage: 300V CAT IV Phase Error: 0.5° Jaw Opening: <15mm diameter or 15x17mm bus bars Errors in % of measuring range at 23°C ± 2K; 74°F±2K, for 48 to 65Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts)

Measuring Range selectable per software:0.2 A to 20 A 2 A to 200 A Peak current for sinusoidal currents74 A 300 A Intrinsic error 0.5% Frequency Range 40 Hz to 10 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening < 15 mm diameter or 15 x 17 mm bus bars Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts)

Category: Pressure

Hose and fittings to connect directly to the Fluke 700HTP-1 test pressure port Includes plugs and caps to eliminate fluid loss in hose, eliminates the need to re-prime the hose. Self-sealing fittings with easy finger tight connections.  Low volumetric expansion and a negligible pressure drop at rated pressures One year warranty Includes:  Hose with (2) 1/4" NPT female output connections (2) adapters that to convert ¼: NPT female to 1/4" NPT male (include sealing caps) 1/4 in NPT female to 1/4 in BSP male adapter  Instruction sheet

One pair (red, black) of nickel plated clips Profile narrows to 5.6 mm at tip, hook opening 6.4mm at front, 2 mm at base Recommended for use with TL222 and TL224 test leads CAT IV 600 V, CAT III 1000 V, 3 A rating. UL listed

Durable nylon construction protects your thermometer while keeping it within reach Velcro closures provide quick access and a secure closure Extra accessory pocket for storing temperature probe Snap-open loop attaches easily to your belt

Measuring Range selectable per software:0.2 A to 20 A 2 A to 200 A Peak current for sinusoidal currents74 A 300 A Intrinsic error 0.5% Frequency Range 40 Hz to 10 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening < 15 mm diameter or 15 x 17 mm bus bars Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts)

Measuring Range selectable per software 1 A to 100 A 5 A to 500 A Peak current for sinusoidal currents 240 A 1350 A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening 45 cm length 2 m cable Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts)