Conductivity Meters

Conductivity is used to measure the ability of an aqueous solution to carry an electrical current, it commonly used to determine concentration of solution, detect contaminants and determine the purity of water. Bante Instruments provides many type of multi-range and multi-parameter conductivity meters for field or laboratory applications.

  • Filter

Bante531 portable conductivity meter used for measuring the electrical conductivity and salinity of liquids. Features: Up to 5-point push-button calibration allows user to uses customized     calibration solutions. Adjustable cell constants, temperature coefficients, normalization     temperature etc. In salinity measurement modes, selectable practical salinity (PSU) or     seawater measurement standard (ppt). Automatic Temperature Compensation (ATC) ensures highly accurate     measurements over the entire range. Manual temperature calibration provides accurate temperature value. Selectable either temperature units between degrees Celsius (°C)     and degrees Fahrenheit (°F). Selectable linear or pure water compensation modes. Calibration due reminder prompts you to calibrate the meter regularly. Automatic endpoint function freezes the stable measured values for     easy reading and recording data. Help message as a operational guide to helps you understand how     to use meter.

Bante540 portable conductivity meter used for measuring the electrical conductivity, TDS, salinity and resistivity of liquids. Features: Up to 5-point push-button calibration allows user to uses customized     calibration solutions. Adjustable TDS factors, cell constants, temperature coefficients and     normalization temperature. In salinity measurement modes, selectable practical salinity (PSU) or     seawater measurement standard (ppt). Automatic Temperature Compensation (ATC) ensures highly accurate     measurements over the entire range. Manual temperature calibration provides accurate temperature value. Selectable either temperature units between degrees Celsius (°C)     and degrees Fahrenheit (°F). Selectable linear or pure water compensation modes. Calibration due reminder prompts you to calibrate the meter regularly. Automatic endpoint function freezes the stable measured values for     easy reading and recording data. Help message as a operational guide to helps you understand how     to use...

DDS-W series conductivity meter are an easy-use basic meters which used for measuring the electrical conductivity of liquids. Automatic Calibration: The meters can calibrate 1 point in each of the measuring ranges.  From Setup Menu, choose calibration and immerse the electrode into standard calibration solution,press ENTER key and meter is automatically calibrated. Auto-Ranging: The meters have auto-range function for measuring conductivity. Upon immersing conductivity cell into sample solution, the meter will immediately displays the values in appropriate measurement range for accuracy.

DDS-W series conductivity meter are an easy-use basic meters which used for measuring the electrical conductivity of liquids. Automatic Calibration: The meters can calibrate 1 point in each of the measuring ranges.  From Setup Menu, choose calibration and immerse the electrode into standard calibration solution,press ENTER key and meter is automatically calibrated. Auto-Ranging: The meters have auto-range function for measuring conductivity. Upon immersing conductivity cell into sample solution, the meter will immediately displays the values in appropriate measurement range for accuracy.

Bante510 benchtop conductivity meter used for measuring the conductivity and TDS of liquids. The meter is widely used in environmental and ecological studies for monitoring the purity and concentration of water. Features: Large backlit LCD display shows mode indicators and help messages. Up to 3-point push-button calibration allows user to uses customized     calibration solutions. Auto-Ranging for conductivity and TDS measurements. Adjustable TDS factors, cell constants and temperature units. Automatic Temperature Compensation (ATC) ensures highly accurate     measurements over the entire range. Automatic endpoint function freezes the stable measured values for     easy reading and recording data. Manual temperature calibration provides accurate temperature value. Help message as a operational guide to helps you understand how     to use meter.

Bante950 is a professional multi-range conductivity meter which used for measuring the conductivity, TDS, salinity and resistivity of liquids. Features: Up to 5-point push-button calibration allows user to uses customized     calibration solutions. Adjustable TDS factors, cell constants, temperature coefficients and     normalization temperature. In salinity measurement modes, selectable practical salinity (PSU) or     seawater measurement standard (ppt). Automatic Temperature Compensation (ATC) ensures highly accurate     measurements over the entire range. Manual temperature calibration provides accurate temperature value. Selectable either temperature units between degrees Celsius (°C)     and degrees Fahrenheit (°F). Selectable linear or pure water compensation modes. Calibration due reminder prompts you to calibrate the meter regularly. Automatic endpoint function freezes the stable measured values for     easy reading and recording data.