GW INSTEK LCR-800 Series

Category: LCR Meters

Features:

※ Test Frequency:
12Hz~200kHz (LCR-821)
12Hz~100kHz (LCR-819/829)
12Hz~10kHz (LCR-817/827)
100Hz~2kHz (LCR-816/826)
※ 0.05%~0.1% Basic Accuracy
※ 100 Sets Memory for Save/Recall of Settings
※ R/Q, C/D, C/R, L/Q, Z/θ, L/R Test Modes
※ Absolute Value,ΔValue, and Δ% Measurement Display
※ 240 x 128 dot Matrix LCD Display
※ Displays Condition and Test Result Simultaneously
※ Standard Interface: RS-232C (LCR-821)/ Handler (LCR-829/827/826)
※ Optional Interface: RS-232C (LCR-819/817/816)

Description:

The LCR-800 Series are high-end digital LCR meters for component/material measurements, applicable to various R&D activities and assembly lines. The large 240 x 128 dot matrix LCD display provides ample room for two measurement items and setup parameters, allowing you to grasp measurement results quickly. All test modes are able to measure supplementary factors, such as, R/Q, C/D, C/R, and L/Q. The LCR-821 also contains precise resistance measurements as a combination of absolute value and phase angle. 100 sets of measurement setup memory allow sharing a single unit among multiple testing conditions or sites. For a better viewing experience in a standard PC monitor, proprietary Windows based software is accessible via the RS-232C terminal. The handler interface is also a standard feature for LCR-826/827/829.

MODEL
LCR-821
LCR-819
LCR-829
LCR-817
LCR-827
LCR-816
LCR-826
Display
240 x 128 dot matrix CCFL back light LCD
Test Frequency
12Hz~200kHz
(504 steps)
12Hz~100kHz
(503 steps)
12Hz~10kHz
(489 steps)
100Hz~2kHz
(245 steps)
Basic Accuracy
0.05%
0.05%
0.1%
0.05%
0.1%
0.05%
0.1%
Test Mode
R/Q, C/D, C/R
L/Q, Z/θ , L/R
R/Q, C/D, C/R,L/Q
R/Q, C/D, C/R,L/Q
R/Q, C/D, C/R,L/Q
Memory
100 memory blocks totally
DC BIAS
Internal
2V
2V
2V
2V
External
0 ~35V
0 ~30V
0 ~30V
0 ~30V
Interface
RS-232
Std.
Opt.
 
Opt.
 
Opt.
 
Handle
 
 
Std.
 
Std.
 
Std.

Specification:

TEST FREQUENCY
  12Hz ~ 200kHz (504 steps) for LCR-821
12Hz ~ 100kHz(503 steps) for LCR-819/829
12Hz ~ 10kHz(489 steps) for LCR-817/827
100Hz ~2kHz (245 steps) for LCR-816/826
BASIC ACCURACY (*)
  0.05% for basic accuracy for LCR-821/819/817
0.1% for basic accuracy for LCR-829/827/826/816
TEST SPEED
  68ms for LCR-821/819/817/816, 34ms for LCR-829/827/826
TEST SIGNAL LEVELS
  5mV ~ 1.275Vrms ( 5mV/step ) for LCR-821/819/829/817/827
0.1V ~ 1.275Vrms ( 5mV/step )for LCR-816/826
DC BIAS
Internal 2V
External 0 ~ 35V for LCR-821; 0 ~ 30V for LCR-819/829/817/827/816/826
DISPLAY RANGE (**)
Resistance R 0.00001Ω ~ 99999kΩ
Capacitance C 0.00001pF ~ 99999uF
Inductance L 0.00001mH ~ 99999H
Quality Factor Q 0.0001 ~ 9999
Dissipation Factor D 0.0001 ~ 9999
Impedance |Z| 0.00001Ω ~ 99999kΩ for LCR-821
Phase Angle (Degree) θ   -180.00° ~ 180.00° for LCR-821
TEST MODE
  R/Q, C/D, C/R, L/Q,
Z/θ, L/R for LCR-821 only
EQUIVALENT CIRCUIT
  Parallel or series selectable
MEMORY
  100 memory blocks total
AVERAGE
  1 to 255 times
TEST SPEED MODE
  SLOW, MEDIUM and FAST
DISPLAY MODE
  Value, △, △%
DISPLAY
  240 x 128 dot matrix C.C.F.L back light LCD
INTERFACE
  Standard  : RS-232C for LCR-821
Standard  : Handler Interface for LCR-829/827/826
Optional : RS-232C Interface for LCR-819/817/816
(Including LCR-Viewer Software for RS-232C interface)
POWER SOURCE
Line Voltage Range 100V - 240V, 47-63Hz/400Hz
DIMENSIONS & WEIGHT
  330(W) x 149(H) x 437(D)mm
Approx. 5.5kg

(*):Basic accuracy varies with the speed, frequency, AC signal level and impedance of the device under test.

(**):Display range refers to the range of measurement values that can be displayed on the screen. Please see the LCR-800 user manual for the effective measurement ranges.

Accessories:

User manual x1, Power cord x1, LCR-06A x1
 
OPTION
Opt. 01 RS-232C Interface ( Factory Installed )
 
OPTIONAL ACCESSORIES
LCR-05  Test Fixture for Axial & Radial Leaded Components
LCR-06A  Kelvin Clip Test Lead
LCR-07  Test Fixture, Two-Wire with Alligator Clips
LCR-08  Test Fixture (Tweezers) for SMD / Chip Components
LCR-09  Test Fixture for SMD / Chip Components
LCR-13  Test Fixture for SMD / Chip Components
GRA-402  Rack Adapter Panel, Rack Mounting (19", 4U)
GTL-232  RS-232 Cable, 9-pin Female to 9-pin, null Modem for Computer
GTC-001  Instrument Cart
GTC-002  Instrument Cart

Ordering Information:

LCR-821 200kHz High Precision LCR Meter with RS-232
LCR-819 100kHz High Precision LCR Meter
LCR-829 100kHz High Precision LCR Meter with Handler Interface
LCR-817 10kHz High Precision LCR Meter
LCR-827 10kHz High Precision LCR Meter with Handler Interface
LCR-816 2kHz High Precision LCR Meter
LCR-826 2kHz High Precision LCR Meter with Handler Interface

Download:

Manual
 
 
Description
 
 
 
     3117 K     LCR-800 Series User Manual (pdf)    en    VK   2012/01/20
     112 K     Command List for LCR-821/819/817/816(pdf)    en    V2.2   2010/05/03

 

Sales Kit
 
 
Description
 
 
 
     226 K     LCR-800 Series Product Information    en    V2   2010/08/10

 

Examples
 
 
Description
 
 
 
     258 K     Usage Hyper-terminal to control LCR-800 series    en    V0   2010/12/31
     598 K     Usage a terminal programmer (Real-term) to control LCR-800 series    en    V0   2010/12/31
     66 K     How to measure a internal resistance of battery by using LCR-800 series    en    V0   2010/12/31
     42441 K     Capability of R measurement    nil    0   2014/5/10
     19491 K     Short the test fixture    nil    0   2014/5/10
     64791 K     Zeroing the test fixtrue    nil    0   2014/5/10

 

Software
 
 
Description
 
 
 
     3391 K     LCR-Viewer For LCR-816 / LCR-817 / LCR-819 / LCR-821 (Vista supported, but not for Win7 64bit)    en    V1.3   2009/9/15

 

 

Location

Ask about this product