* Professional bench type milliohm meter.* 20 m /200 m /2 /20 /200 /2 K /20 K ohm.* 20,000 counts, Jumbo LCD with back light.* Hi / Lo warning, 4 wires terminals, Kelvin clips is included, 0.001 milliohm resolution.* Judgement output : Low/Good/High port, used for the automatic machine to select the components (good or no good).* Power : AC 110V or AC 220 V/AC230 V.
FEATURES* 4 terminal devices for accurate measurement of very low resistance.* Ideal for measuring the resistance of components precisely.* Ideal for testing protective conductors, lightning conductors and welded points.* Maximum test current is 10A ( 60000uΩ range only ).* Have two working mode , Resistive and Inductive mode, Normal is resistive mode.* Good / Fail set-function for input quality control.* Built-in in buzzer sound (GOOD STATUS) to assist the Q.C. judgment.* Especial "CALCULATE" function to measure cable / wire length.
Features: •Analysis for 3 phase multi-power system, 1P/2W, 1P/3W,3P/3W, 3P/4W •3 current probes ( CP-1201 ) are included, if change the current probes, the calibration procedures are not necessary •Current probe input signal/ranges with selection:Input signal (ACV):200 mV/300 mV/500 mV/1 V/2 V/3 VRanges (ACA) : 20 A/200 A/2000 A/30 A/300 A/ 3000 A. •Meter can cooperate the universal current probes •Measurement: V (phase-to-phase), V (phase-to-ground) A (phase-to-ground) KW / KVA / KVAR / PF (phase) KW / KVA / KVAR / PF (system) KWH / KVAH / KVARH / PFH (system) Phase angle •Harmonics display (1-50th order) •Simultaneous display of Harmonics and Wave form •Display of Waveform with Peak Values •Analysis of Total Harmonic Distortion ( THD ) •Graphic Phase diagram with 3-Phase system parameters •3 phase Voltage or Current Unbalanced Ratio ( VUR, AUR ) and Unbalanced Factor •Calculated Unbalanced Current through Neutral Line ( An ) Standard Accessories: * Instruction manual............... 1 PC * Test Leads (TL88-4AT).......... 1 Set (4 PCs) * Alligator clips (TL88-4AC) 1 Set (4 PCs) * Clamp Probe ( CP-1201 )....... 3 PCs * AC to DC 9V adapter..............1...
Features: •Analysis for 3 phase multi-power system, 1P/2W,1P/3W, 3P/3W, 3P/4W •Voltage & Current are the True RMS value. •True Power ( KW、MW、GW ) measurement. •Apparent Power ( KVA、MVA、GVA ) measurement. •Reactive Power ( KVAR MVAR、GVAR) measurement. •Watt-Hour ( WH、SH、QH、PFH ). •Power Factor( PF )、Phase Angle( Φ ). •Voltage measurement range : 10 to 600 ACV •Current measurement range: 0.2A to 1200 ACA. •Programmable CT ratio (1 to 600) and PT ratio (1 to 1000). •ACV input impedance is 10 Mega ohms. •Safety Standard : IEC 1010, CAT III 600V •Built-in clock and Calendar, real time data record with SD memory card , sampling time set from 2 to 7200 seconds. Just slot in the SD card into the computer, it can down load the all the measured value with the time information ( year/month/data/hour/mimute/second ) to the Excel directly, then user can make the further data analysis by themselves. •Measurement: * ACV * ACA * AC WATT ( True Power )AC WATT( Apparent Power )AC WATT( Reactive Power ) * Power factor * Phase angle * Frequency Standard Accessories: * Instruction manual.......................1 PC * Test Leads...
0.1 W resolution ( <1000 W ), high precision and high resolution in the low watt range, good performance , for low power LED lamp watt measurement Supper large LCD, easy to read-out, display the Watt, Power factor, Voltage & Current value at the same time. Accept different kinds current input signal as direct input, inductive clamp probe or CT ( current transformer ). Auto range. Built-in peak hold & data hold function. RS-232 output interface. Power supply by batteries or AC to DC adapter. - See more at: http://www.test-measurement-australia.com.au/electrical/lutron-dw-6090a#sthash.oTAjYKvQ.dpuf Multi-functions: Watt, VA, W hr, Power factor, ACV, ACA, DCV, DCA, Hz, ohm True AC power measurement, not apparent power True RMS for ACV and ACA Display Watt, power factor, V and A simultaneously Auto range, Peak-hold and Data-hold RS-232 serial output interface Watts (AC true power) Direct input: 1W-100kW Current probe: 1W-2,000kW VA(AC) Direct input: 0.01VA-40kVA Power Factor: 0.01-1.00 ACV/DCV 0.1V-600V ACA/DCA Direct input: 0.01A-20A Current probe: 1A-1000A Watt Hour Direct input:...
Features Excellent accuracy of (1.1+0.6L/600)μm with 0.1μm/0.5μm resolution/repeatability. Perpendicularity (frontal) of 5μm and straightness of 4μm are guaranteed. Pneumatic full/semi-floating system allows adjustment of air-cushion height. Basic statistical functions are provided and, additionally, RS-232C / USB data output provides the option of evaluating measurement data externally with SPC software on a PC. One-key operation for running a semi-automatic measurement. Data entry from a Digimatic tool.
* High quality product with 2 years warranty. LED VS XENON - It can measure 10 times wider range with the much higher emission frequency at the FPM of 500,000 FPM, than that of 30,000FPM of Xenon Lamp - It can use for a long time with lamp life over 10,000 hours - It can measure area at the RPM of 15~250,000(used Double RPM Check) with the FPM of 15~500,000 - It is very bright because using white power LED through over-current control Reliability of Measurement - Realizing measurement accuracy below 0.0125% with fully digital method (15~120,000 FPM) - Preventing measurement errors by variation at the multiples of integers (2,3,4,5... 21) and measuring fast - Equipped with function deciding the direction of rotating bodies LED VS XENON - It can measure 10 times wider range with the much higher emission frequency at the FPM of 500,000 FPM, than that of 30,000FPM of Xenon Lamp - It can use for a long time with lamp life over 10,000 hours - It can measure area at the RPM of 15~250,000(used Double RPM Check) with the FPM of 15~500,000 - It is very bright because using white power LED through over-current control Reliability of Measurement - Realizing...
* Complete set, meter + humidity probe (MS-71P).* Stainless Humidity content probe, used to measure the humidity content value for the materials of Grain, Corn, Rice. Cotton, Paper...* Function : Humidity content , Dew point, Type K Thermometer.* Humidity content : 10 to 95 %RH.* Type K Temp. : -100.0 to 1300.0 oC* Thin-film capacitance sensor for humidity content measurement.* Data hold, Record (Max., Min.).* RS232/USB computer interface.* Probe (MS-71P) size : 10 mm Dia. x 600 mm length.